The following guidelines are based on the requirements of the State Prevention Code. Assistance in using these guidelines and meeting the requirements of the State Fire Prevention code is available from the Department of Environmental Safety (DES) Fire Marshal's Office.
Fire Marshal (301) 405-3970
Deputy Fire Marshal (301) 405-7489
FAX (301) 314-9294
Pager: Through University of Maryland Police (301) 405-3555
| Occupant Load (floor area of tent) | Number of Exits (minimum) |
|---|---|
| 49 (343 sq ft) or less | 1 |
| between 50 (350 sq ft) and 499 (3,493 sq ft) | 2 |
| between 500 (3,500 sq ft) and 999 (6,993 sq ft)* | 3 |
| 1000 or more (7,000 sq ft) | 4 (more exits may be needed) |
net square footage of tent floor area / 15 = occupant load with tables and chairs
Example: The number of occupants allowed, with tables and chairs, in a 50'X50' tent with a 10'X20' stage.2,500 square feet (floor area) - 200 square feet (stage area) / 15 = 153 persons
Please Note: These calculations are for planning purposes only and do not represent a legal capacity. The DES Fire Marshal's Office will provide legal capacities based on submitted set-up plans.
|